Section 2 · Water Heaters

Tank Water Heater Problems and Repair Guides

A tank water heater keeps a full tank hot, with cold water entering low and hot water leaving from the top. Sediment, a worn anode rod and the T&P relief valve explain many of its problems. Start with the problem table, then use the upkeep schedule to add years to the tank.

DiagnoseIt's leaking or there's water around itNot sure what is wrong? Answer a few quick questions to find the likely cause

Start with the symptom

Fig. 1Parts of a gas tank water heater
Parts of a gas tank water heaterFront view of a gas tank water heater with the front cut away to show the inside. Nine numbered parts: 1 flue running up through the center of the tank to the vent; 2 cold inlet pipe on top, left; 3 hot outlet pipe on top, right; 4 anode rod hanging from a port on top; 5 T&P valve on the upper right side with its discharge pipe running down to just above the floor; 6 dip tube carrying cold water down inside the tank; 7 gas valve on the front; 8 burner under the tank; 9 drain valve near the bottom.123456789FlueCold inletHot outletAnode rodT&P valveDip tubeGas valveBurnerDrain valve
  1. Flue and vent Pro only

    On a gas heater, hot combustion gases from the burner rise through a flue in the center of the tank and leave through the vent on top. A poorly vented water heater can leak carbon monoxide into the home, so vent problems are work for a pro.[5][3]

  2. Cold water inlet and shutoff DIY

    Cold water enters on top. The shutoff valve on this line stops the tank from refilling. Close it whenever the heater leaks.[2][6] Where to shut it off: Cold water inlet and shutoff

  3. Hot water outlet DIY

    Heated water leaves from the top of the tank. Its fitting, like the cold one, is one of the places a heater can leak.[2][7] Fix a dripping fitting: Hot water outlet

  4. Anode rod DIY with care

    A metal rod that slowly corrodes so the glass-lined tank does not. A. O. Smith says to pull it for inspection every 3 years, or every year with softened water.[2] If the port leaks: Anode rod

  5. Temperature and pressure (T&P) relief valve and discharge pipe Test only; a pro replaces it

    This safety valve opens to release water if the tank gets too hot or the pressure climbs too high; it is normally rated for 210°F and no more than the tank’s working pressure, generally 150 psi. Its discharge pipe must end no more than 6 inches above a floor drain, or outside, and must never be capped or plugged.[8][2] T&P valve checks: Temperature and pressure (T&P) relief valve and discharge pipe

  6. Dip tube Pro only

    The cold inlet feeds a tube that carries incoming water down toward the bottom of the tank. That lets the heated water rise to the top, where the outlet draws it off.[9][2]

  7. Gas control valve and thermostat Pro only

    The gas control valve holds the thermostat that sets the water temperature. A. O. Smith and NFPA point to about 120°F to lower the risk of scalds.[2][3] If it is wet here: Gas control valve and thermostat

  8. Burner Pro only

    On a gas heater the burner sits under the tank and heats the water from below. An electric heater has no burner; heating elements do the job instead.[5] Pilot or burner won’t stay lit: Burner

  9. Drain valve DIY

    Used to drain the tank and flush out sediment. A. O. Smith recommends draining and flushing every 6 months.[2] If it drips: Drain valve

  • Electric models. An electric tank has no burner, gas valve or flue. Most have two heating elements, wired so they do not heat at the same time.[5]
  • Rating plate. The rating plate on the tank lists the model and serial numbers you need for parts, service and warranty questions.[2]
Original diagram. Simplified — your unit may look different.

How a tank water heater works

A storage water heater keeps a tank of water hot and ready. When you open a hot tap, heated water flows out of the top of the tank. Cold water enters at the bottom to replace it.⁠[1] The cold inlet feeds a dip tube inside the tank, which is how the new water reaches the bottom.⁠[2] Gas models heat the water with a burner. Electric models use upper and lower heating elements inside the tank.⁠[1]

Three parts guard the tank. The thermostat holds the temperature you set, and NFPA advises 120°F to lower the risk of scald burns.⁠[3] The temperature and pressure (T&P) relief valve exists to stop the tank from reaching excessive temperature or pressure.⁠[2] The anode rod slowly wears away so the glass-lined tank does not corrode. Once the rod is used up, the tank starts to corrode and in time it leaks.⁠[2]

Water also carries minerals. As it heats, dissolved calcium and magnesium fall out as lime scale and settle with soil and sand at the bottom of the tank.⁠[2] That layer lowers heating efficiency, can cause rumbling and pounding noises, and shortens the life of the heater.⁠[2]

Each of these parts can cause a symptom you can see, hear or smell. Water on the floor, a noisy tank, a rotten-egg smell and a pilot that keeps going out each start at one of these parts. The diagram on this page shows where each part sits, and the table below starts from the symptom.

Safety basics for tank water heaters

Never cap or plug the T&P valve or its discharge pipe, and never put a valve between the relief valve and the tank. The valve must stay in its own opening, and its pipe must end at a suitable drain or outside the building.⁠[2] If the valve keeps releasing water after a manual test, close the cold water inlet and have the valve replaced with a properly rated one.⁠[2]

A pilot that goes out again and again, or is hard to light, can signal a safety problem. NFPA says not to fix it yourself and to have a fuel gas professional relight it.⁠[3]

Common tank water heater problems and the first check

Start with the row that matches what you see. Each first check is safe for an owner and needs no tools.

SymptomFirst checkGuide
Water around the heaterWipe the area dry, then look up the tank for drips at the pipe connections before you look at the base.find the leak source step by step
Puddle that seems to start at the bottomCheck whether the drain valve outlet is wet, since that valve sits low on the tank.—
Pilot light keeps going outFollow the manufacturer's lighting instructions once, and if the pilot goes out again, call a gas professional.⁠[3]gas pilot that won't stay lit
Unsure how old the tank isFind the rating plate and write down the model and serial numbers.⁠[2]—
Big repair quote on an older tankCompare the tank's age with the roughly 10-year life a 2007 NAHB study found for gas models.⁠[4]weigh the repair against a new tank

A heater that sat in flood water is a separate case. A. O. Smith says flood damage may not be visible, and that a flooded water heater must be replaced, not repaired.⁠[2]

Tank water heater maintenance and expected life

Flush the tank to remove sediment. The A. O. Smith gas manual recommends draining and flushing every 6 months.⁠[2] Its flushing steps follow this order:

  1. Turn off the electrical supply to the heater.
  2. Leave the cold water inlet open, run a nearby hot tap until the water is no longer hot, then close the tap.
  3. Connect a hose to the drain valve, secure the far end at a drain and open the valve.
  4. Let water flow under supply pressure until it runs clean, then close the valve, refill the tank and restore power.

Other models may add steps, so follow the manual for your heater.

Check the anode rod. The same manual says to remove the rod for inspection every 3 years, or every year if your water is softened.⁠[2] It calls a rod depleted when most of its diameter is under 3/8 inch. Bare core wire along about a third of its length is the other sign.⁠[2] Never remove the anode for good. A. O. Smith says that voids the tank warranty, and it offers a special rod for water that smells like rotten eggs.⁠[2]

Test the T&P valve. A. O. Smith recommends checking that it works every 6 months, with no one near the discharge outlet, because the water may be extremely hot.⁠[2]

Watch for thermal expansion. Heated water expands, and in a closed system with a check valve or pressure reducing valve the pressure rises with it.⁠[2] That can make the relief valve drip and can cause early tank failure, so A. O. Smith requires a properly sized expansion tank on closed systems.⁠[2]

Set the temperature with care. University of Maryland Extension says 120°F is enough for most households and can cut water heating energy use by 6 to 10 percent.⁠[1]

Expect a tank to wear out. A 2007 NAHB study put the life of a gas water heater at about 10 years and an electric one at about 11.⁠[4] Tankless units age on a different curve; all water heater repair guides cover both types.

Sources

  1. University of Maryland Extension · Nonprofit

    “Home Energy: Water Heating” · accessed

  2. A. O. Smith · Manufacturer manual

    “Instruction Manual: Residential Gas Water Heaters, Power Vented Models (100341945)” · PDF · pp. 7, 13-16 (components, scald table, T&P valve, thermal expansion), pp. 39-41 (periodic maintenance) · accessed

  3. National Fire Protection Association · Safety org

    “NFPA Educational Messages Desk Reference, 2026 Edition” · PDF · §3.1.3, §3.11, §9.2.1, §19.3.1 · accessed

  4. National Association of Home Builders / Bank of America Home Equity · Trade association

    “Study of Life Expectancy of Home Components” · PDF · Table 1, p. 10 (Water Heaters, Electric and Gas) · accessed

  5. U.S. Department of Energy, Building America · Government

    “Strategy Guideline: Proper Water Heater Selection” · PDF · §1.4.1, p. 6 · accessed

  6. A. O. Smith · Manufacturer support

    “Why Is My Water Heater Leaking?” · accessed

  7. A. O. Smith · Manufacturer support

    “Technical Bulletin 51: Puddle on Floor” · accessed

  8. A. O. Smith · Manufacturer support

    “Technical Bulletin 52: Leaking Temperature & Pressure Relief Valve” · accessed